UPO33

3 PHASE INDUSTRIAL

UPO33 80 / 100 / 120 PF365

Quick Specs

  • Capacity: 80kVA 72kW
  • Input Connector: 3 phases+N+PE
  • Power Factor:0,9 (Efficiency calculated at room temperature </= a 30°C / 86°F)
  • Waveform: Sinusoidal wave
  • Weight: UPS 1,089 Kg / Cabinet of batteries with batteries 690 Kg
  • Protection: Autotest, transfer point , battery and audible alarm
  • Voltage: 120/208 (380, 480 or other voltages for request)
  • Current Crest: 3:1
  • System efficiency: More than 92%
  • Overload capacity: 125% for 12 minutes / 150% for one minute
  • Connection: Triphase 5 Threads (3 phases + neutro +ground)
  • Filters: EMI,RFI
  • Frequency: 60Hz +/-10%
  • Battery Cabinet (WxHxD): 800x1900x980mm
  • Emergency Power: EPO localn / remote
  • Design Technology: True online (double conversion) with inverter based in IGBT´s)
  • Capacity: 100kVA 90kW (Calculated at </= a 30°C / 86°F)
  • Input Connector: 3 phases+N+PE
  • Power Factor: 0,9 (Efficiency calculated at room temperature </= a 30°C / 86°F)
  • Waveform: Sinusoidal wave
  • Weight: UPS 1,136 Kg / Cabinet of batteries without batteries 710 Kg
  • Protection: Autotest, transfer point , battery and audible alarm
  • Voltage: 120/208 (380, 480 or other voltages for request) line to line +/-20% full load
  • Current Crest: 3:1
  • System efficiency: More than 92%
  • Overload capacity: 125% for 12 minutes / 150% for one minute
  • Connection: Triphase 5 Threads (3 phases + neutro +ground)
  • Filters: EMI,RFI
  • Frequency: 60Hz +/-10%
  • Battery Cabinet (WxHxD): 800x1900x980mm
  • Emergency Power: EPO local / remote
  • Design Technology: True online (double conversion) with inverter based in IGBT´s)
  • Capacity: 120kVA 108kW
  • Input Connector: 3 phases+N+PE
  • Power Factor: 0,9 (Efficiency calculated at room temperature </= a 30°C / 86°F)
  • Waveform: Sinusoidal wave generated by low investor logic of modulation PWM a
  • Weight: UPS 1,319 Kg / Cabinet of batteries with batterie 1010 Kg
  • Protection: Autotest, transfer point , battery and audible alarm
  • Voltage: 120/208 (380, 480 or other voltages for request) line to line +/-20% load
  • Current Crest: 3:1
  • System efficiency: More than 92%
  • Overload capacity: 125% for 12 minutes / 150% for one minute
  • Connection: Triphase 5 Threads (3 phases + neutro +ground)
  • Filters: EMI,RFI
  • Frequency: 60Hz +/-10%
  • Battery Cabinet (WxHxD): 800x1900x980mm
  • Emergency Power: EPO local / remote
  • Design Technology: True online (double conversion) with inverter based in IGBT´s)

DOWNLOAD

Catalogs

SPANISH

NOT AVAILABLE

ENGLISH

NOT AVAILABLE

CDP Energy ©2020 All rights reserved.